Functional Unit Constraints
4-45PipelineSPRU733
Table 429 shows the instruction constraints for MPYSP instructions
executing on the .M unit.
Table 429. MPYSP .M-Unit Instruction Constraints
Instruction Execution
Cycle 1 2 3 4
MPYSP R W
Instruction Type
Subsequent Same-Unit Instruction Executable
MPYSPDP 
MPYSP2DP

Instruction Type
Same Side, Different Unit, Both Using Cross Path Executable
Single-cycle
Load 
Store

DP compare

2-cycle DP

Branch

4-cycle

INTDP

ADDDP/SUBDP
Legend: = E1 phase of the single-cycle instruction; R = Sources read for the instruction; W = Destinations written for the
instruction;
= Next instruction can enter E1 during cycle